Request a quote
Engineering · Manufacturing · Automation

Gas distribution equipment that runs without an operator

We design, manufacture, program and commission automated gas distribution stations, odorization units, gas heaters and control systems — complete units with a high level of process automation.

  • Complete units: cleaning, heating, pressure reduction, metering, odorization
  • Own PLC/SCADA software, integration with dispatch centres
  • Work in hazardous (Ex) zones with all required permits
Process chain of a gas distribution station
CleaningHeatingPressure reductionMeteringOdorizationMain pipeline1.2 – 7.5 MPaConsumers0.2 – 1.2 MPa
1 000 – 100 000Nm³/h
capacity range of Energia stations
±1 °C
gas temperature control accuracy of PG heaters
±5 %
odorant dosing error of odorization complexes
72 h
autonomous operation on backup power
Products

Products

Process units and systems for gas distribution stations, compressor stations and main pipelines.

All products
AGDS “Energia”

Automatic gas distribution stations “Energia”

Complete block stations for 1 000 – 100 000 Nm³/h: cleaning, heating, pressure reduction, metering and odorization without an operator.

Learn more
SAU GRS

Automatic control systems for gas distribution stations (SAU GRS)

PLC/SCADA system that maintains the set gas distribution process, protects consumers and prevents emergencies.

Learn more
KlOG

Gas odorization complex “KlOG” (valve type)

Pulsed gravity dosing of odorant through solenoid valves in proportion to gas flow. Simple and reliable solution for stations of small and medium capacity.

Learn more
KOG

Gas odorization complex “KOG” (pump type)

Injection of odorant by an electromagnetic diaphragm metering pump in proportion to gas flow — for stations up to 400 000 m³/h and pressures up to 5.5 MPa.

Learn more
PG heaters

Gas heaters type PG

Natural gas heaters with an intermediate heat carrier for heating gas before pressure reduction; temperature control accuracy ±1 °C.

Learn more
BUZP

Pig launcher and receiver units “BUZP”

Units for launching into the pipeline and receiving in-line inspection tools, cleaning pigs and other flow devices.

Learn more
Gas cleaning

Gas cleaning units

Filter separators and dust collectors for removing mechanical impurities and liquid from gas before reduction and metering.

Learn more
Process tanks

Process tank units

Above-ground and underground tanks for condensate, odorant and methanol with level monitoring and safe discharge.

Learn more
Heat exchangers

Shell-and-tube heat exchanger units

Gas–liquid and liquid–liquid heat exchangers in a block design for gas heating and heat recovery systems.

Learn more
Services

Systems we implement

Over the years the company has completed a number of projects automating gas cleaning, heating, pressure reduction, metering and odorization units, with data exchange with adjacent systems and remote dispatch centres.

  • 01

    Automated control systems for gas distribution stations

    Maintaining the set process of gas distribution, protection of consumers, control of shut-off and regulating valves, communication with dispatch centres.

  • 02

    Control systems for gas heating units

    Automatic maintenance of the set gas temperature before and after pressure reduction, burner and safety automation.

  • 03

    Video surveillance systems at facilities

    IP video surveillance of station sites and perimeter with archive and transmission to the dispatch centre.

  • 04

    Room gas concentration monitoring

    Detectors of methane and other gases, alarm thresholds, forced ventilation control and shut-off.

  • 05

    Fire detection systems

    Addressable fire detection and alarm systems for process buildings and control rooms.

  • 06

    Site security systems

    Perimeter security, access control, intrusion alarm with integration into the common site SCADA.

  • 07

    Process communication systems

    Radio, fibre-optic and GSM channels for data transmission between the station and the dispatch centre; redundancy.

  • 08

    Automatic pump-type odorization units

    Injection of odorant by a metering pump in proportion to the gas flow rate; up to 400 000 m³/h.

  • 09

    Automatic valve-type odorization units

    Pulsed dosing of odorant by gravity through solenoid valves; simple and reliable solution for smaller stations.

Why customers choose us

Process piping and valves of a gas distribution station
GDS site

Full cycle in one place

Design, optimal equipment selection, manufacturing, programming and commissioning — a single responsible contractor.

Safety by design

Equipment is designed for operation in explosive zones; automatic protection against unsafe parameter deviations and early detection of emergencies.

Open integration

Modbus TCP / RS-485 interfaces, 'dry contact' signals and data exchange with the upper-level SCADA of the gas transmission operator.

Long service life

Service life of at least 12 years, MTBF of at least 30 000 hours, maintenance interval of 2 years.

Permits and licences

Permits and licences

The company holds all permits required to carry out work in hazardous zones.

  • Permit for work in hazardous areas
  • Licence for construction of facilities with significant liability consequences
  • Equipment designed in accordance with EU directives PED 2014/68/EU and ATEX 2014/34/EU
Request a quote

Request a quotation

Tell us about your site: gas flow rate, inlet and outlet pressure, required functions. We will prepare a technical proposal within 3 working days.

By submitting the form you agree to the processing of your data for the purpose of answering your request.